STP真空絕熱板在施(shi)工中(zhong),需要注意很多要點(dian)。比如說,基(ji)礎墻應(ying)平直。應(ying)清(qing)除和(he)(he)清(qing)理妨礙(ai)粘(zhan)貼的壁(bi)偏(pian)差、凸(tu)起、凹陷、松動(dong)和(he)(he)污垢。接著就是水(shui)泥(ni)砂漿找平,用(yong)2m直尺檢查墻面平整(zheng)度(du),誤差范圍在2mm以(yi)內。
對于(yu)彈簧控(kong)制線,先確定水平和垂(chui)直基(ji)準線,根據立面(mian)確定的切口設(she)計,使用(yong)待粘(zhan)貼墻(qiang)面(mian)上的基(ji)準線彈出(chu)保溫(wen)板布置圖。嚴格按照界面(mian)比例,用(yong)滾筒刷在陰涼干(gan)燥(zao)處干(gan)燥(zao)2小(xiao)時(shi)。
每種配(pei)置(zhi)粘(zhan)(zhan)(zhan)結砂漿(jiang)不(bu)易過(guo)多(duo),應(ying)(ying)在(zai)45分鐘內使用(yong)(yong)完。按(an)照布置(zhi)圖將板粘(zhan)(zhan)(zhan)貼(tie)在(zai)墻(qiang)上,板的(de)(de)外露面(mian)用(yong)(yong)網布翻轉。粘(zhan)(zhan)(zhan)貼(tie)方(fang)式為(wei)條粘(zhan)(zhan)(zhan)貼(tie),粘(zhan)(zhan)(zhan)接(jie)面(mian)積不(bu)小(xiao)于60%,粘(zhan)(zhan)(zhan)接(jie)順序為(wei)自(zi)下而上,按(an)水平(ping)(ping)線施工。粘(zhan)(zhan)(zhan)貼(tie)時(shi)應(ying)(ying)均勻擠壓,可(ke)用(yong)(yong)橡(xiang)皮錘輕敲固(gu)定。粘(zhan)(zhan)(zhan)結砂漿(jiang)的(de)(de)壓實(shi)厚(hou)度應(ying)(ying)控(kong)制在(zai)3-5mm以內,板面(mian)應(ying)(ying)嚴格控(kong)制平(ping)(ping)面(mian)度和垂直度應(ying)(ying)隨時(shi)用(yong)(yong)2米斜尺和拖線板檢(jian)查。
STP真空絕熱板(ban)粘貼(tie)后,使用導(dao)熱系(xi)數小(xiao)于0.07瓦特的無機保(bao)溫砂漿(jiang),通過一平方米用于面(mian)板(ban)接(jie)縫(feng)填充施工。填充前,應對(dui)面(mian)板(ban)接(jie)縫(feng)進行(xing)處理,清除灰塵和其他雜質。接(jie)著就(jiu)是(shi)鉆孔(kong)、安裝錨固(gu)件、涂膠(jiao),等(deng)做(zuo)好(hao)系(xi)列步驟之(zhi)后,需要進行(xing)整體檢查。